Danfoss Thermostatic Expansion Valves
Danfoss Thermostatic Expansion Valves

Danfoss Thermostatic Expansion Valves

MOQ : 1 Number

Danfoss Thermostatic Expansion Valves Specification

  • Valve Size
  • Suitable for 0.5 TR to 80 TR systems
  • Valve Type
  • Thermostatic Expansion Valve
  • Features
  • High control accuracy, fast response, compact design, easy installation
  • Connection Type
  • Flare, solder, or threaded
  • Control System
  • Thermostatic sensing bulb
  • Material
  • Brass, stainless steel, and copper
  • Voltage
  • Not applicable (non-electric)
  • Sealing
  • PTFE or elastomeric seals
  • Application
  • Refrigeration and air conditioning systems
  • Structure
  • Thermostatic expansion valve with sensing bulb
  • Type
  • External or Internal equalization
  • Power
  • Manual (non-electric operation)
  • Pressure
  • Maximum working pressure up to 35 bar
  • Media
  • Refrigerant
  • Port Size
  • 1/4 inch to 1-1/4 inch
  • Temperature
  • -40C to +10C
  • Disc
  • High precision brass
  • Pin
  • Corrosion-resistant stainless steel
 

Danfoss Thermostatic Expansion Valves Trade Information

  • Minimum Order Quantity
  • 1 Number
  • Supply Ability
  • 3 Per Day
  • Delivery Time
  • 24 Hours
 

About Danfoss Thermostatic Expansion Valves

We have been engaged in exporting and supplying a broad array of Danfoss Thermostatic Expansion Valves. At our trusted vendors ends, adroit professionals use optimum quality raw materials and sophisticated techniques to manufacture the offered valves as per set industry standard. Best suited in refrigerators and air conditioning systems, provided valves are used to control the amount of refrigerant flow into the evaporator. In addition, our valuable patrons can easily avail these Danfoss Thermostatic Expansion Valves at cost effective rates from us.

Features:
  • Strongly design
  • Long working life
  • Requires low maintenance
  • Supreme finish



Precision Superheat Control

The Danfoss Thermostatic Expansion Valves allow users to finely tune the superheat via an external adjustment feature. This results in enhanced system efficiency and reliable temperature control, both crucial for refrigeration and air conditioning applications requiring optimal performance.


Versatile Application & Compatibility

Engineered to work with common refrigerants such as R22, R134a, R404A, R407C, R410A, and R507, these valves cover a wide temperature range (-40C to +10C) and can be installed in numerous system sizes (0.5 TR to 80 TR), making them suitable for a variety of commercial, industrial, and HVAC environments.


Reliable Construction and Easy Service

Built from high-quality brass, stainless steel, and copper, Danfoss valves combine durability with a compact design for straightforward installation. Field-replaceable components, secure clamp-on bulb mounting, and minimal leakage rates ensure hassle-free servicing and long-term system integrity.

FAQs of Danfoss Thermostatic Expansion Valves:


Q: How can the superheat setting be adjusted on Danfoss thermostatic expansion valves?

A: The superheat setting on Danfoss expansion valves can be externally adjusted using the accessible adjustment screw. This allows technicians to fine-tune the system for optimal efficiency and temperature control without dismantling the valve.

Q: What refrigerants are compatible with Danfoss thermostatic expansion valves?

A: These valves are compatible with a wide range of refrigerants, including R22, R134a, R404A, R407C, R410A, R507, and other common types, providing flexibility for many different cooling systems.

Q: When should you consider servicing a Danfoss thermostatic expansion valve?

A: Regular inspections are recommended as part of routine system maintenance. You should service the valve if you notice irregular system performance, a drop in efficiency, or after extended operational periods, as the valves have field-serviceable and replaceable components.

Q: Where can Danfoss thermostatic expansion valves be installed?

A: These valves can be mounted inline or on a bracket, and are suitable for use in both refrigeration and air conditioning systems across commercial and industrial sites throughout India.

Q: What is the process for installing the sensing bulb on Danfoss expansion valves?

A: The sensing bulb should be securely mounted onto the suction line using the provided stainless steel clamp. This ensures precise temperature measurement and responsive superheat control.

Q: What benefits do Danfoss thermostatic expansion valves offer?

A: They deliver high control accuracy, fast thermal response, minimal refrigerant leakage, and long operational life. The adjustable superheat and broad compatibility make them an excellent choice for efficient system performance and reliable operation.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Refrigeration and Air Conditioning Valves Category

Danfoss Externally Operated Valves

Danfoss Externally Operated Valves

Price 5000 INR / Number

Minimum Order Quantity : 1 Number

Power : Other, Externally operated, does not require electrical power

Structure : Other, Angle type and straight type body available

Media : Other, Refrigerants, liquids, gases

Pressure : Other, Up to 28 bar (dependent on model)

Danfoss Electronic Control Valve

Danfoss Electronic Control Valve

Price 5000 - 50000 INR / Number

Minimum Order Quantity : 1 Number

Power : Other, Electronic, low power consumption

Structure : Other, Direct operated valve

Media : Other, Refrigerant gases

Pressure : Other, Maximum operating pressure up to 45 bar

Danfoss Strainers

Danfoss Strainers

Price 2000 - 50000 INR / Number

Minimum Order Quantity : 1 Number

Power : Other, Manual (Nonelectric)

Structure : Other, YStrainer Type, Inline Housing

Media : Other, Refrigerants, Gases, Liquids

Pressure : Other, Max. 25 bar (363 psi)

Danfoss Water Regulating Valves

Danfoss Water Regulating Valves

Price 5000 - 30000 INR / Number

Minimum Order Quantity : 1 Number

Power : Other, Manual/Automatic (Nonelectric)

Structure : Other, Directoperated, Pistonactuated Valve

Media : Other, Water, Glycol Mixtures

Pressure : Other, Maximum working pressure: 25 bar



Back to top